Product Details:
|
Usage: | Sand And Dust Testing Chamber | Air Pressure: | 86~106kpa |
---|---|---|---|
Powder Type: | Talcum Powder | Pressure Tolerance: | 0~2kpa |
Testing Time: | 0~999h88m99s, Adjustable | Blower: | Centrifugal Fan |
Blowing Dust Cycle: | Interval Control, Adjustable | Door Material: | Tempering Glass |
Weight: | 400kg | Power Supply: | AC380V, 50/60Hz, Three Phase |
Highlight: | ingress protection test equipment,ingress protection testing |
IP5 / IP6 IP Test Equipment Sand and Dust Test Chamber with LCD Touch Screen
HD-E706 Dust Test Chamber - IP5X&6X.pdf
Product Description:
The IP5 / IP6 LCD Touch Screen Lamp Sand and Dust Testing Equipment is suitable housing sealing performance testing products, mainly for IP5X and IP6X two levels of test enclosure class specified in the standard. The main damage is simulated sandstorms on locks, automobile and motorcycle parts, seals, power meters and other products caused.
The test object:
① phone, electrical products and other goods and tightness in sand and dust environment.
② automobile and motorcycle parts, seals and other sand and dust in the environment of use, storage, transport sealing performance.
Features of IP5 / IP6 LCD Touch Screen Lamp Sand and Dust Testing Equipment:
1. Formed using CNC machining box, nice shape, and no reaction by the handle, easy to operate.
2. Imported high grade stainless steel inner tank (SUS304) mirror panels, use of A3 steel box outside the gall spray, increasing the appearance of the texture and cleanliness.
3. Equipment containing dust vertical circulation of air, dust can be reused for testing; device itself has a good sealing performance, test, laboratory test can clearly observe the situation; device equipped with a vacuum system to meet the needs test; equipment dust the bottom of the device can be replaced.
4. Large observation window with bright lights to keep the box, and use of tempered glass embedded heating element, at any time a clear observation box condition.
5. Test with 50mm diameter holes for the external test power line or signal line.
Dust aging chamber control system:
1, the controller: LCD microcomputer programmable logic controller. Time Control PLC programmable logic controller to complete the time and order of blowing dust, vibration, vacuum system controls.
2, the vacuum system: with pressure gauge, air filter, regulator FRL connecting pipe.
3, circulating fan: low noise motors, leafy centrifugal wind wheel.
Main Technical Parameters of IP5 / IP6 Lamp Sand and Dust Testing Equipment:
Item |
Specification |
Inner chamber size |
120 * 120 * 120cm |
External size |
170 * 150 * 190cm (approx.) |
Air pressure |
86~106kpa |
Studio temperature |
RT~60'C, adjustable |
Amount of talcum powder |
2kg per cubic meter of the test chamber volume Can not have been used for more than 20 tests |
Powder type |
Talcum powder |
Aspirator flowing quantity |
0~6L/min |
Pressure tolerance |
0~2kpa |
Metal net size |
Wire diameter 50um, width of a gap between wires 75um |
Testing time |
0~999h88m99s, adjustable |
Blower |
Centrifugal fan |
Blowing dust cycle |
Interval control, adjustable |
Chamber material |
SUS#304 stainless steel |
Door material |
Tempering glass |
Control interface |
LCD touch screen |
Vacuum system |
Pressure gauge, air filter, Pressure regulating FRL, connecting pipe, Vacuum pump |
Weight |
400kg |
Power supply |
AC380V, 50/60Hz, three phase |
Chamber Structure:
Housing material: high quality steel spray.
Liner material: imported SUS stainless steel light board.
Sight glass door for easy observation test cabinets test sample status.
Bottom of the chamber can be fixed with high quality PU wheels.
Replace the bottom of the chamber has a dust devices.
Reliable pneumatic vibration means.
Strong dust hair motors, blowing dust and ensure free fall
A band with a piping bag mica heating coil, heat the security and stability (to prevent adhesion of dust caking).
Heating control with timing.
Dust Testing Equipment troubleshooting methods:
1, dust chamber no electricity power meter does not light: Check the power supply is normal, check the phase sequence is normal, whether the zero line.
2, do not blow dust: Check the blower fan is working properly or is too small, check the dust is dry.
3, does not vibrate: Check vibration motor is normal.
4, there should be someone Shachenshiyanxiang management operations, and regular cleaning of the blower housing and regular maintenance should be professionals.
5, in order to stably play chamber function, performance, select a constant temperature of between fifteen to twenty-five degrees, relative humidity less than 85% of the space.
6, the distance between adjacent walls or between objects. Installation site ambient temperature should not abruptly change five should be installed in a place without direct sunlight, should be installed in a well ventilated place, away from the place combustible, explosive and high temperature heat source, the equipment should be installed in a dusty little place, do It may be installed near the power supply place.
7, the device no power: Check the power supply is normal, check the phase sequence is normal, whether the zero line.