High Accuracy Thermal Shock Air Test Chamber Shock Thermal Tester PID+SSR(control method)

High Accuracy Thermal Shock Air Test Chamber Shock Thermal Tester PID+SSR(control method)

    • High Accuracy Thermal Shock  Air Test Chamber Shock Thermal Tester PID+SSR(control method)
    • High Accuracy Thermal Shock  Air Test Chamber Shock Thermal Tester PID+SSR(control method)
    • High Accuracy Thermal Shock  Air Test Chamber Shock Thermal Tester PID+SSR(control method)
  • High Accuracy Thermal Shock  Air Test Chamber Shock Thermal Tester PID+SSR(control method)

    Product Details:

    Place of Origin: China
    Brand Name: HaiDa
    Certification: ISO,CE
    Model Number: HD-E703

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: Negotiation
    Packaging Details: Strong Wooden Case
    Delivery Time: 15 Days After Order
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability: 75 Piece / Pieces Per Month
    Contact Now
    Detailed Product Description
    Usage: High And Low Temperature Thermal Shock Test Chamber Setting Range:: TEMPERATURE : -100.00+200.00°C
    Refrigerant:: Environment-friendly R23/404a High Temperature Range:: From 60℃ To 200℃
    Allowable Ambient Conditions: +5~30°C Power Supply: AC380V, 50/60Hz, Three Phase , 30A
    Cooling Water Supply Pressure*6: 02~0.4Mpa

    High Accuracy Thermal Shock Air Test Chamber Shock Thermal Tester PID+SSR(control method)

     

     

    Thermal Shock Chamber.pdf

    1. Description:

     

    High Accuracy Thermal Shock Air Test Chamber Shock Thermal Tester PID+SSR(control method) is the perfect testing machine of electronic components, metal, chemical materials, automation components, communication module, national defense industry, aerospace industry, BGA, PCB substrate, electronic chip IC, semiconductor ceramic and high polymer materials.

     

     

    2. Specifications of High Accuracy Thermal Shock Air Test Chamber Shock Thermal Tester PID+SSR(control method)r:

     

    System Two-zone test by means of damper switching
    Three-zone chamber
    Model HD-E703-50A/HD-E703-50W HD-E703-100A/HD-E703-100W Customized
    Performance Test area High temp. exposure range*1 +60~ to +200°C
    Low temp. exposure range*1 -65to 0 °C
    Temp. fluctuation *2 ±1.8°C
    Hot chamber Pre-heat upper limit +200°C
    Temp. heat up time*3 Ambient temp. to +200°C within 30min
    Cold chamber Pre-cool lower limit -65°C
    Temp. pull down time*3 Ambient temp. to -65°C within 70min
    Temp. recovery (2-zone) Recovery conditions Two-zone: High temp. exposure +125°C 30 min, Low temp. exposure -40°C 30 min; Specimen 6.5 kg (specimen basket 1.5kg)
    Temp. recovery time Within 10 min.
    Construction External material Cold-rolled rust-proofed steel plate
    Test area material SUS304 stainless steel
    Door*4 Manually operated door with unlock button
    Heater Strip wire heater
    Refrigeration unit System*5 Mechanical cascade refrigeration system
    Compressor Hermetically sealed scroll compressor
    Expansion mechanism Electronic expansion valve
    Refrigerant High temp side:R404A, Low temp side R23
    Cooler Stainless steel welded plate heat exchanger
    Air circulator Sirocco fan
    Damper driving unit Air cylinder
    Fittings Cable port with diameter 100mm on the left side (right side and tailor made diameter size are available as options), specimen power supply control terminal
    Inside dimensions (W x H x D) 350 x 400 x 350 500 x 450 x 450 Customized
    Test area capacity 50L 100L Customized
    Test area load 5 kg 10 kg Customized
    Outside dimensions (W x H x D) 1230 x 1830 x 1270 1380 x 1980 x 1370 Customized
    Weight 800kg 1100kg N/A

     

    Utility requirements

     

    Allowable ambient conditions +5~30°C
    Power supply AC380V, 50/60Hz, three phase , 30A
    Cooling water supply pressure*6 02~0.4Mpa
    Cooling water supply rate*6 8m³ /h
    Operating cooling water temp. range +18 to 23 °C
    Noise Level 70 dB or lower
     
     

    Notes

     

    1. If the high-temp exposure range lower limit + 60°C is required or the low temp exposure range lower limit -60°C, please select the “ambient-temperature exposure” option

     

    2. If the temp fluctuation need to below ±1.8°C please select the “Low temp fluctuation package”

     

    3. Temperature heat-up/pull down time are applicable only during independent chamber operation

     

    4. If the automatically operated sliding door required, please select the “Automatically door package”

     

    5. Air-cooled condenser / Water-cooled condenser both available

     

    6. Apply on water-cooled condenser only

     

     

    3. Safety Devices of High Accuracy Thermal Shock Air Test Chamber Shock Thermal Tester PID+SSR(control method)

    1. Hot chamber overheat protection switch
    2. Cold chamber overheat protection switch
    3. Air circulator overload alarm
    4. Refrigerator high/low pressure protector
    5. Compressor temperature switch
    6. Air pressure switch
    7. Fuse
    8. Water suspension relay ( water-cooled specification only)
    9. Compressor circuit breaker
    10. Heater circuit breaker
    11. Test area overheat/overcool protector
    12. Air purge valve

     

    Control

     

    Operation and settings simplified by the use of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, and trend graph displays.

     

    Setting Interactive key input by touch panel
    Display LCD (5.7 inches)
    Temperature control function

    Test area: exposure temp.

    Hot chamber: pre-heating temp.

    Cold chamber: pre-cooling temp.

    PID control
    Preset temperature range

    High temperature: 60 to200’C

    Low temperature: -78 to 0’C

    Setting resolution 1’C
    Input Thermocouple type T (Copper/Copper-Nickel)
    Setting and indication ranges

    Preset time: 0 min. to 99 hours and 59 min.

    Preset cycle: 1 to 9,999 cycles

    Accessory function

    Timer preset

    Overheat/ overcool protection

    Power failure/ recovery selection

    Temperature recovery time setting

    Program memory

    Automatic power shut-off

    Programmed time display

    Test completion mode selection

    Trend graph

    Alarm history display

    Sensor calibration

    RS-232/ USB communication

     

     

    4. High Accuracy Thermal Shock Air Test Chamber Shock Thermal Tester PID+SSR(control method)view:

     

    High Accuracy Thermal Shock  Air Test Chamber Shock Thermal Tester PID+SSR(control method)

     

     

     

    (The Test Chamber)

     

     

     

     

    High Accuracy Thermal Shock  Air Test Chamber Shock Thermal Tester PID+SSR(control method)

    High Accuracy Thermal Shock  Air Test Chamber Shock Thermal Tester PID+SSR(control method)

     

    Contact Details
    Hai Da Labtester

    Contact Person: Mr. Liang

    Send your inquiry directly to us (0 / 3000)

    Other Products
    Hai Da Labtester
    6th Floor, Rongda Building, Yuanwubian Road, Nancheng District, Dongguan, Guangdong, China (Mainland)
    Tel:86-769-89201068
    Privacy Policy China Good Quality Lab Test Machines Supplier. Copyright © 2015 - 2019 labtestmachines.com. All Rights Reserved.