Product Details:
|
Humiture Range: | 30-98%RH | Rainfall Cycle: | 1-240min |
---|---|---|---|
Certificate: | ISO9001: 2008 | Warranty Period: | 12 Months |
Studio Size: | 95Dx95Wx90Hcm | Box Material: | Stainless Steel SUS304# |
Insulation Materials: | Superfine Glass Fabric | Control System: | Germany KLOCKNER-MOELLER Progammable Controler |
Gas Processing: | Dischager For Fector And Harmful Gas | Use Environment: | 5°C~+30°C, ≤85%R.H |
Highlight: | ozone test chamber,xenon test chamber |
Sunlight Simulation Xenon Aging Chamber UV and Daylight Arc Aging Chamber
HD-E711 Xenon Aging Test Chamber - Air cooled.pdf
Product Introduction:
Xenon Aging Chambe is the ultimate research & development and quality control tool for testing materials that are exposed to direct sunlight, sunlight through window glass or indoor lighting.and applicable to testing aging speed. And that can determine the tensile force and elongation about material before and after test. Usually thought test sample in 70℃within the tester 24 hours, approximately is equal to the natural environment six months.It can test rubber,plastic,LED and etc.
Features:
Key Features:
Remarkably Simple User Interface
AUTOCAL Calibration
Full Spectrum Xenon Lamps
Long-Life Optical Filters
Programmable Water Spray
SOLAR EYE Irradiance Control
Precision Temperature Control
Versatile Specimen Mounting
Relative Humidity Control
Specifications:
Model | HD-711L Xenon Lamp Aging Chamber |
Inner Box Size (D×W×H) | 950×950×900mm |
Outside Dimension (D×W×H) | 1300×1500×1900mm |
Humiture Range | (RT+10)~70°C; 30~98%RH |
Humiture uniformity | ± 2°C; ± 3%RH |
Rainfall time | 1~9999min, adjustable |
Rainfall cycle | 1~240min, interval is adjustable |
Xenon lamp light | xenon long-arc lamp, 6KW±10%, 290-800nm, 1000W/m2±200 |
Heating/humidifying power | 2.0KW/2.0KW |
Sample spinning machine speed | 1~5r/ min (adjustable) |
Sample and xenon lamp distance | 300~375mm |
Box material | Stainless Steel SUS304# |
Insulation materials | Superfine heat insulation cotton |
Insulation body | Superfine glass fabric |
Circulation system | Single cycle, centrifugal fan |
Control system | Germany KLOCKNER-MOELLER progammable controler |
Gas processing | dischager for fector and harmful gas |
Power | AC380V, three phase five wire, 10KW |
Use environment | 5°C~+30°C, ≤85%R.H |
Standard features | 1. Filtering screen viewing window; 2.Moistureproof lamp |
Security Protection | Security device for circuit break, |
high pressure of the compressure, high temperature alarm |
Simple to Use:
Sunlight Simulation xenon aging chamber UV and Daylight Arc Aging Chamber are easy to install, easy to program and easy to operate.Specimen mounting and evaluations are simplified with specially designed specimen holders. All models are completely automated and can operate continuously, 24 hours per day, 7days per week, without supervision. The testers are smart enough to alert you to problems they may encounter during
testing.
Auxiliary Structure:
Seal: double high-temperature high tensile seal between the door and the cabinet in order to ensure that the test area
Door handle: no reaction door handle, easier to operate
Moves the sample holder: Sample holder rely installation box at the bottom of the linear reciprocating drive system for moving up and down
Casters: bottom of the machine can be fixed with high quality PU wheels
Air Circulation Device:
Built-in air-conditioned rooms, circulation air duct and the long axis of the centrifugal fan, the use of energy efficient refrigerators and conditioning systems, through efficient fan for effective exchange of the purpose of the temperature change. By improving the flow of air, improve air flow and the heater and air cooler heat exchange capacity, thereby significantly improving the temperature uniformity of the chamber.
Cooling System:
US dry filters, solenoid valve Italy
Multi-wing strong air circulation blower, to avoid any dead ends, xenon lamp aging chamber allows a uniform distribution of temperature and humidity within the test area.
Air duct return air design cycle of wind, air pressure wind speed are in line with testing standards, and can open the door the moment the temperature and humidity stabilization time soon.
Heating, cooling, humidification system is completely independent can improve efficiency and reduce testing costs, increase life expectancy and lower failure rate
Control System:
3.1 Display: color touch screen and PLC module control, automatic handwriting settings, intuitive user interface, overall nice, simple and easy to operate
3.2 Curve recording function: real-time display of temperature and humidity curve may have a history memory function (available historical records test within 7 days)
3.3 Display Resolution: Accuracy: 0.1 ℃ (display range), resolution: ± 0.1 ℃, Humidity: 0.1% RH (temperature and humidity test equipment)
3.4 Subsidiary function: fault alarm and reason, the process prompts, power protection, upper and lower temperature protection function, calendar timer function (automatic start and stop automatically), self-diagnostic function, with automatic calculation function can be warm humidity conditions corrected immediately
3.5 temperature sensor:. PT100 platinum resistance temperature body
3.6 Control: heat balance humidity thermostat way, using the same temperature and humidity control channel P.I.D + S.S.R coordinated control system with automatic calculation function, temperature and humidity conditions can be amended immediately so that more precise and stable temperature and humidity control
Xenon Lamp Aging Chamber Care And Maintenance:
1, at any time to maintain a neat appearance;
2. Do not place objects on top of the machine to heat parts of Lima Da and control;
3, xenon lamp aging chamber after long-term use, spare parts, motor blower unit, wheel deceleration devices, if abnormal noise, should be checked, and pay attention to regular cleaning fuel;
4, electrical components such as over-temperature phenomena, must be checked immediately causes;
5, after each use, a xenon lamp aging test chamber should be kept clean to prevent corrosion;
6, the control cabinet clean-up once a month to prevent excessive dust, affecting the normal operation of equipment;
7. After the test is complete, you should turn off the main power, water stains wipe clean indoor work, try to keep the chamber in a dry environment;
8, the electrical components on the control panel, such as the need to exchange failure occurs, Do not indiscriminate demolition ensure xenon lamp aging chamber life.