Product Details:
|
Chamber Temperature: | 25~50℃;Resolution:0.1℃ | Blackboard Temperature Range: | 40~85℃ Accuracy:±1℃ |
---|---|---|---|
Blackboard Temperature Range ( Option): | 40~80℃ Accuracy:±2℃ | Time Control Experiments: | ≤10000h |
Xenon Arc Lamp Rated Power: | 2.5KW | Dimensions: | 1000×550×1570mm |
Highlight: | textile testing instruments,fabric testing equipment |
Electronic Textile Xenon Lamp Air Cooled Light Fastness Tester / Textile Leather Tester
Products description:
Machine is mainly determine the color fastness and aging to sunlight, weather resistance, compound color fastness to sunlight-perspiration of colored textile, leather, leatheroid, plastic, etc, by setting various parameters of irradiance, temperature, humidity, spray to simulate natural condition in lab. With Rain, revolution, rotation and spray resistance etc, climate functions.
Usage:
To determine color fastness to water and perspiration in textiles. It’s also employed to predict the potential of white or pastelcoloured textiles to yellow in transit or storage.
Standards:
GB/T 8427 ISO105-B02 GB/T8430 ISO105-B04 GB/T14576
AATCC TM16-2003 GB/T15102-2006 GB/T15104-2006
Features:
Products parameter:
Function mode |
Offering light, rain ,alternating light and dark, revolution, rotation. The alternation light and dark is meet with AATCC4 standard. The Xenon lamp light automatically turns on and off in accordance with a certain proportion of time ( Instead of the previous sample holder 180 degree Tipping ) And temperature and humidity changes according to the standard. |
Chamber Temperature | 25~50℃;Resolution:0.1℃ |
Chamber Humidity |
Light Cycle:10~70%RH;Resolution:0.1% Dark Cycle:30~95%RH;Resolution:0.1% |
Blackboard temperature range | 40~85℃ Accuracy:±1℃ |
Blackboard temperature range ( Option) | 40~80℃ Accuracy:±2℃ |
Time control experiments | ≤10000h |
Irradiance range
|
0.80~2.01W/m2@420nm;(Option: 340nm,420nm,300-400nm and 300-800nm)Accuracy:±0.02W/m2@420nm. Digital setting,Closed-loop automatic compensation |
Xenon arc lamp rated power | 2.5KW |
Sample holder rotation speed | revolution 5r/min;rotation.:180°/ture(could be customized) |
Sample holder can be mounted with the number of dimensions |
GB:135×45mm 12pcs AATCC:100×75mm 6pcs Both sides can clip the sample |
Timing of each sample holder, respectively, | ≤10000h |
Photoperiod | ≤1000h |
Spray cycle | ≤1000h |
Power | AC220V±10% 50Hz 5.0KW . Rated power 2.5KW |
Dimensions | 1000×550×1570mm |
Weight | 180kg |
Contact Person: Mary
Fax: 86-0769-89280809