Product Details:
|
Usage: | Constant Temperature Humidity Chamber | Temp. Range: | -70°C~150°C |
---|---|---|---|
Humid. Range: | 10~ 98 Percent R.H. | Resolution: | 0.01°C, 0.1 Percent, P.I.D Control |
Interior Dimension(W×D×H): | 100×100×80cm | Interior Material: | Stainless Steel Plate(SUS304) |
Display: | LCD | Weight: | Approx. 600 Kg |
Power: | AC220V±10 Percent 50/60Hz | ||
Highlight: | electronic lab equipment,lab testing equipment |
Lab temperature chamber Door opening alarm Temperature Humidity Chamber can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material.
1. Specifications of Stainless Steels Constant Temperature Humidity Chamber Climate Test Equipment:
Range – 70 to 150°C
Temp/Humidity | HD-E702-100-7 | HD-E702-150-7 | HD-E702-225-7 | |
HD-E702-408-7 | HD-E702-800-7 | HD-E702-1000-7 | ||
Temp-only | HD-E702-100T-7 | HD-E702-150T-7 | HD-E702-225T-7 | |
HD-E702-408T-7 | HD-E702-800T-7 | HD-E702-1000T-7 | ||
Temperature Range: | -70°C ~150°C | |||
Cooling Capacity | ~ 2.5 kW at -50°C | ~ 3 kW at -50°C | ~ 5 kW at -50°C | |
~ 6.5 kW at-50°C | ~ 8.5 kW at -50°C | ~ 9 kW at - -50°C | ||
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW | |
~6.5 kW | ~ 8.5 kW | ~ 9 kW | ||
Temperature Fluctuation: | ±0.5°C | |||
Temperature Gradient: | ±0.5°C~±0.2°C | |||
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) | |||
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) | |||
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) | |||
Humidity Fluctuation: | ±1.5%RH~±2.0%RH | |||
Humidity Gradient: | ±3%RH | |||
Dimensions | ||||
Workspace dimensions (WxDxH)mm: |
500x400x500 HD-E702-100 |
600x500x500 HD-E702-150 |
750x500x600 HD-E702-225 |
|
850x650x800 HD-E702-800 |
1000x1000x800 HD-E702-800 |
1000x1000x1000 HD-E702-1000 |
||
Exterior dimensions (WxDxH)mm: |
1400x850x1050 | 1500x950x1050 | 1650x950x1150 | |
1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 | ||
Site Requirements | ||||
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) | |||
Humidity Water | Distilled water | |||
Condensate Drain: | 1/2" hose connection (gravity drain) |
Range – 40 to 150°C
Temp/Humidity | HD-E702-100-4 | HD-E702-150-4 | HD-E702-225-4 | |
HD-E702-408-4 | HD-E702-800-4 | HD-E702-1000-4 | ||
Temp-only | HD-E702-100T-4 | HD-E702-150T-4 | HD-E702-225T-4 | |
HD-E702-408T-4 | HD-E702-800T-4 | HD-E702-1000T-4 | ||
Temperature Range: | -40°C ~150°C | |||
Cooling Capacity | ~ 2 kW at -20°C | ~ 2.5 kW at -20°C | ~ 4.5 kW at -20°C | |
~ 5.5 kW at-20°C | ~ 8 kW at -20°C | ~ 8.5 kW at - -20°C | ||
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW | |
~6.5 kW | ~ 8.5 kW | ~ 9 kW | ||
Temperature Fluctuation: | ±0.5°C | |||
Temperature Gradient: | ±0.5°C~±0.2°C | |||
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) | |||
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) | |||
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) | |||
Humidity Fluctuation: | ±1.5%RH~±2.0%RH | |||
Humidity Gradient: | ±3%RH | |||
Dimensions | ||||
Workspace dimensions (WxDxH)mm: |
500x400x500 HD-E702-100 |
600x500x500 HD-E702-150 |
750x500x600 HD-E702-225 |
|
850x650x800 HD-E702-800 |
1000x1000x800 HD-E702-800 |
1000x1000x1000 HD-E702-1000 |
||
Exterior dimensions (WxDxH)mm: |
1400x850x1050 | 1500x950x1050 | 1650x950x1150 | |
1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 | ||
Site Requirements | ||||
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) | |||
Humidity Water | Distilled Water | |||
Condensate Drain: | 1/2" hose connection (gravity drain) |
2. Performance
Get a performance evaluation to help provide the suitable chambers to you.
For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.
Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.
Questions for Performance Evolution Request:
System & Performance Options
(Normal Humidity Range Diagramed)
3. Features of Stainless Steels Constant Temperature Humidity Chamber Climate Test Equipment:
Vice lock type door and foam silicone packing to ensure a perfect seal Cartridge type tank for easy adding and changing of water
Tempered glass window with lamps provides a clear view of samples in the chamber, beneficial during testing Easy cleaning of condenser air-filter to prevent deterioration of refrigeration system
Leakage breaker for power supply Over current protection Overheat / overcool protection Switch-off after alarm for over heating Water empty / Door open alarm Vice lock door type locking mechanism
Standard Features:
4. Stainless Steels Constant Temperature Humidity Chamber Climate Test Equipment view:
Contact Person: Mary
Fax: 86-0769-89280809