Product Details:
|
Usage: | Constant Temperature And Humidity Testing Machine | Temp. Range: | -70°C~150°C |
---|---|---|---|
Humid. Range: | 10~ 98 Percent R.H. | Temp. & Humid. Regularity: | ± 1°C; ± 3 Percent RH |
Heating Up: | -40°C ~ +100°C Within 45 Min | Heating Down: | 20°C~ -20°Cwithin 40min |
Exterior Dimension(W×D×H): | 145x190x135cm | Interior Material: | Stainless Steel Plate(SUS304) |
Weight: | Approx. 600 Kg | Power: | AC220V±10 Percent 50/60Hz |
Highlight: | Constant Temperature And Humidity Chamber,Temperature Humidity Test Chamber |
Constant Temperature And Humidity Chamber Laboratory Test Machine
HD-E702-100-7 Climate Chamber.pdf
Introduction:
Constant Humidity and Temperature Control Test Machine is tested for performance index about the relate components and material of the electron, motors, aviation, ship weapon and high college research institutions and so on under the cyclic changes in high and low temperature.
International Applications
HD series chambers meet international test performance standards. The units can be installed around the world for consistent testing at different facilities, supported by Haida Group and our cooperation prater in Australia, Dubai, India, Malaysia, Turkey and Vietnam. And our chambers feature two levels of overheat protection, and one levels of overcool protection. The system controller provides alarm messages with specific troubleshooting help to quickly resume testing.
1. Features of Constant Humidity and Temperature Control Test Machine:
The HD series chambers have temperature change rates from 1 to 3°C per minute in average and controlled humidity from 10% to 95%. There are 6 sizes with interior volumes of 100 to 1000 Liters or we also provide tailor-made chambers of size. On the advance model for Cycling Chambers have temperature change rates from 3 to 15 °C, controlled humidity from 10 to 95%.
Standard Features:
2. Specifications of Constant Humidity and Temperature Control Test Machine:
Range – 40 to 150°C
Temp/Humidity |
HD-E702-100-4 |
HD-E702-150-4 |
HD-E702-225-4 |
|
|
HD-E702-408-4 |
HD-E702-800-4 |
HD-E702-1000-4 |
|
Temp-only |
HD-E702-100T-4 |
HD-E702-150T-4 |
HD-E702-225T-4 |
|
|
HD-E702-408T-4 |
HD-E702-800T-4 |
HD-E702-1000T-4 |
|
Temperature Range: |
-40°C ~150°C |
|||
Cooling Capacity |
~ 2 kW at -20°C |
~ 2.5 kW at -20°C |
~ 4.5 kW at -20°C |
|
~ 5.5 kW at-20°C |
~ 8 kW at -20°C |
~ 8.5 kW at - -20°C |
||
Heating System |
~ 5 kW |
~ 5 kW |
~ 5.5 kW |
|
~6.5 kW |
~ 8.5 kW |
~ 9 kW |
||
Temperature Fluctuation: |
±0.5°C |
|||
Temperature Gradient: |
±0.5°C~±0.2°C |
|||
Heating Rate†: |
≥3℃ / min average ( Advance model 5 – 15 ℃ / min) |
|||
Cooling Rate†: |
≥1℃ / min average (Advance model 5 - 15℃ / min) |
|||
Humidity Range: |
10%~95%RH (Ref to Normal Humidity Range Diagramed) |
|||
Humidity Fluctuation: |
±1.5%RH~±2.0%RH |
|||
Humidity Gradient: |
±3%RH |
|||
Dimensions |
||||
Workspace dimensions |
500x400x500 HD-E702-100 |
600x500x500 HD-E702-150 |
750x500x600 HD-E702-225 |
|
|
850x650x800 HD-E702-800 |
1000x1000x800 HD-E702-800 |
1000x1000x1000 HD-E702-1000 |
|
Exterior dimensions |
1400x850x1050 |
1500x950x1050 |
1650x950x1150 |
|
|
1750x1050x1350 |
1900x1450x1350 |
1900x1450x1550 |
|
Site Requirements |
||||
Electrical Supply: |
208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) |
|||
Humidity Water |
Distilled Water |
|||
Condensate Drain: |
1/2" hose connection (gravity drain) |
Range – 70 to 150°C
Temp/Humidity |
HD-E702-100-7 |
HD-E702-150-7 |
HD-E702-225-7 |
|
|
HD-E702-408-7 |
HD-E702-800-7 |
HD-E702-1000-7 |
|
Temp-only |
HD-E702-100T-7 |
HD-E702-150T-7 |
HD-E702-225T-7 |
|
|
HD-E702-408T-7 |
HD-E702-800T-7 |
HD-E702-1000T-7 |
|
Temperature Range: |
-70°C ~150°C |
|||
Cooling Capacity |
~ 2.5 kW at -50°C |
~ 3 kW at -50°C |
~ 5 kW at -50°C |
|
~ 6.5 kW at-50°C |
~ 8.5 kW at -50°C |
~ 9 kW at - -50°C |
||
Heating System |
~ 5 kW |
~ 5 kW |
~ 5.5 kW |
|
~6.5 kW |
~ 8.5 kW |
~ 9 kW |
||
Temperature Fluctuation: |
±0.5°C |
|||
Temperature Gradient: |
±0.5°C~±0.2°C |
|||
Heating Rate†: |
≥3℃ / min average ( Advance model 5 – 15 ℃ / min) |
|||
Cooling Rate†: |
≥1℃ / min average (Advance model 5 - 15℃ / min) |
|||
Humidity Range: |
10%~95%RH (Ref to Normal Humidity Range Diagramed) |
|||
Humidity Fluctuation: |
±1.5%RH~±2.0%RH |
|||
Humidity Gradient: |
±3%RH |
|||
Dimensions |
||||
Workspace dimensions |
500x400x500 HD-E702-100 |
600x500x500 HD-E702-150 |
750x500x600 HD-E702-225 |
|
|
850x650x800 HD-E702-800 |
1000x1000x800 HD-E702-800 |
1000x1000x1000 HD-E702-1000 |
|
Exterior dimensions |
1400x850x1050 |
1500x950x1050 |
1650x950x1150 |
|
|
1750x1050x1350 |
1900x1450x1350 |
1900x1450x1550 |
|
Site Requirements |
||||
Electrical Supply: |
208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) |
|||
Humidity Water |
Distilled water |
|||
Condensate Drain: |
1/2" hose connection (gravity drain) |
3. Performance of Temperature and Humidity Controlled Test Machine:
Get a performance evaluation to help provide the suitable chambers to you.
For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.
Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.
Questions for Performance Evolution Request:
System & Performance Options
4. Programmable Constant Humidity and Temperature Control Test Machine view
(Innovative high-speed airflow suited for fast temperature cycling applications)
(Advanced refrigeration design is especially compact for HD-Series Chambers)
Contact Person: Mary
Fax: 86-0769-89280809