Product Details:
|
Product Nmae: | Gas Chromatography | Program Heating Rate: | 0.1~120℃/min(Incremental 0.1℃) |
---|---|---|---|
Maximum Operating Temperature: | 450℃ | Minimum Detectable Limit: | ≤2.5pgC/s [n-C16] |
Dynamic Linear Range: | ≥107(±10%) | ||
Highlight: | electronic lab equipment,laboratory testing equipment |
HPLC Gas Chromatography Testing Machine Used For Quantitative And Qualitative Analysis
Product Description:
Gas chromatograph is used for quantitative and qualitative analysis to determine the physical and chemical constants such as the distribution coefficient, activity coefficient, molecular weight and surface area of the sample in the fixed phase. An instrument for analyzing the components of a mixed gas.
Column temperature Box | |||
Furnace Size | 28×30×18cm | ||
Temperature control Range | Above room temperature5℃~450℃;Using liquid nitrogen cold traps:-80℃~400℃;Using dry ice traps:-55℃~400℃ | ||
Temperature setting accuracy | 0.1℃ | ||
Maximum program heating rate | 120℃/min | ||
Maximum once method run time | 999.99min | ||
Program temperature maximum order | 7 stages | ||
Program heating rate | 0.1~120℃/min(Incremental 0.1℃) | ||
Operation Column loss compensation (dual channel) | |||
Heating Zone | |||
6 independent control Heating zone control (excluding furnace temperature, two inlet, two detectors, two auxiliary heating area auxiliary heating zone maximum operating temperature ) | |||
300℃ | |||
Detectors | |||
Hydrogen Flame Ionization detector FID | |||
Maximum operating temperature | 450℃ | ||
Minimum detectable limit | ≤2.5pgC/s [n-C16] | ||
Dynamic linear range | ≥107(±10%) | ||
Data acquisition frequency | The highest: 100Hz | ||
Thermal conductivity cell detector TCD | |||
Maximum operating temperature | 400℃ | ||
Minimum detectable limit | <400pg C3H8/ml(He) | ||
Dynamic linear range | 105(±5%) | ||
data acquisition frequency | The highest: 100Hz | ||
Flame photometric detector FPD | |||
Maximum operating temperature | 250℃ | ||
Minimum detectable limit | <4pgC/sec,<1pg P/sec | ||
Selective | 105gS/gC,106gP/gC | ||
Dynamic linear Range | >103S,>104P | ||
Electronic Capture Detector ECD | |||
Maximum operating temperature | 400℃ | ||
Detector compensation Gas Type | 5% Methane/Argon or nitrogen | ||
Minimum detectable limit | <0.01Ppg/s lindane | ||
Dynamic linear range | >5×1055 | ||
data acquisition frequency | Max 100Hz | ||
Radioactive sources | <12mCi 63Ni | ||
Nitrogen and phosphorus detectors NPD | |||
Maximum operating temperature | 450℃ | ||
Minimum check out limit | <0.2 pg N/sec,<0.2 pg P/sec | ||
Dynamic linear Range | 105N,105P | ||
Minimum detection limit | <0.3pg C/Sec | ||
The above detectors are suitable for filling column and capillary column | |||
Optional configuration | |||
Anti-control software | Automatic Feed b6891n |
The table parameters is for the company Standard Model parameters, we support customer customization parameters
Advanced Power Distribution Management shunt
A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply
Automatic Feed
8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)
With Automatic online detection function
Precision temperature control of the heating furnace
Furnace internal control accuracy less than 0.01°c
The temperature difference between the internal points is not more than the °c
Rapid heating and cooling, the highest program heating speed: 120℃/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)
Why Choose Us?
1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator.
2. Excellent After sale Service:
18 months warranty. Besides, we can help you to repair your problem controller freely, even it's not from our factory. What you need to do is to send us the controller.