Product Details:
|
Name: | Gas Chromatography | Furnace Size: | 28×30×18cm |
---|---|---|---|
Temperature Setting Accuracy: | 0.1℃ | Maximum Program Heating Rate: | 120℃/min |
Highlight: | electronic lab equipment,laboratory testing equipment |
GLPC/GC Gas Chromatography Mass Spectrometry Lab Test Machines
Product Description:
Gas Chromatograph is used for quantitative and qualitative analysis to determine the physical and chemical constants such as the distribution coefficient, activity coefficient, molecular weight and surface area of the sample in the fixed phase. An instrument for analyzing the components of a mixed gas.
Application industry
1. Analysis of dissolved gas in transformer oil;
2. Analysis of ethylene oxide in medical devices.
3. Analysis of coke oven gas;
4. Pesticide residue analysis;
Alcohol analysis in blood; 5.
6. Analysis of natural gas and liquefied gas;
7. Indoor environment TVOC analysis;
8. Analysis of liquor components;
9. High purity gas analysis;
10. Detection of solvent residue of packaging materials.
Column temperature Box | |||
Furnace Size | 28×30×18cm | ||
Temperature control Range | Above room temperature5℃~450℃;Using liquid nitrogen cold traps:-80℃~400℃;Using dry ice traps:-55℃~400℃ | ||
Temperature setting accuracy | 0.1℃ | ||
Maximum program heating rate | 120℃/min | ||
Maximum once method run time | 999.99min | ||
Program temperature maximum order | 7 stages | ||
Program heating rate | 0.1~120℃/min(Incremental 0.1℃) | ||
Operation Column loss compensation (dual channel) | |||
Heating Zone | |||
6 independent control Heating zone control (excluding furnace temperature, two inlet, two detectors, two auxiliary heating area auxiliary heating zone maximum operating temperature ) | |||
300℃ | |||
Detectors | |||
Hydrogen Flame Ionization detector FID | |||
Maximum operating temperature | 450℃ | ||
Minimum detectable limit | ≤2.5pgC/s [n-C16] | ||
Dynamic linear range | ≥107(±10%) | ||
Data acquisition frequency | The highest: 100Hz | ||
Thermal conductivity cell detector TCD | |||
Maximum operating temperature | 400℃ | ||
Minimum detectable limit | <400pg C3H8/ml(He) | ||
Dynamic linear range | 105(±5%) | ||
data acquisition frequency | The highest: 100Hz | ||
Flame photometric detector FPD | |||
Maximum operating temperature | 250℃ | ||
Minimum detectable limit | <4pgC/sec,<1pg P/sec | ||
Selective | 105gS/gC,106gP/gC | ||
Dynamic linear Range | >103S,>104P | ||
Electronic Capture Detector ECD | |||
Maximum operating temperature | 400℃ | ||
Detector compensation Gas Type | 5% Methane/Argon or nitrogen | ||
Minimum detectable limit | <0.01Ppg/s lindane | ||
Dynamic linear range | >5×1055 | ||
data acquisition frequency | Max 100Hz | ||
Radioactive sources | <12mCi 63Ni | ||
Nitrogen and phosphorus detectors NPD | |||
Maximum operating temperature | 450℃ | ||
Minimum check out limit | <0.2 pg N/sec,<0.2 pg P/sec | ||
Dynamic linear Range | 105N,105P | ||
Minimum detection limit | <0.3pg C/Sec | ||
The above detectors are suitable for filling column and capillary column | |||
Optional configuration | |||
Anti-control software | Automatic Feed b6891n |
The table parameters is for the company Standard Model parameters, we support customer customization parameters
Performance characteristics
1. Inlet flow rate, chromatographic column load airflow, detector gas flow, complete EPC control
Micro-channel Air Circuit Integrated Board
All-imported miniature proportional valves and flow/pressure sensors Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi
2. Industry-Leading detector design
All detectors are high-precision electronic flow/pressure control
Fit and fill column and capillary column Special ceramic treatment of the enlarged plate, in the humid season is always stable
Automatic ignition, hydrogen leak automatic protection function, safe and reliable
Packaging & Shipping:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
Our Services
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.
1. Pre-service
24 Hours online service for your consult.
Help choose right model,and a series of service,person,advise.
2. Middle service
--Give you best offer
--Provide discount for many sets order
--Do customer's request:
--Choose payment term you convienent.
--Promptly production and delivery,inform you in time.
--Can provide invoice value as you like to decrease your tax.
3. After sale service
--1 year warranty service and all life maintenance.
--Technical Egineer are avalible for oversea trainning.
--Free change for some parts
--Remote control technical consult
--Free installation DVD
--Maintenance plan
4,Commitment:
We will sign a letter of commitment while we sign the contract, which will improve your confidence to us.
5,Good Packaging:
Good Packaging: Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.
Contact Person: Mary
Fax: 86-0769-89280809