Home ProductsTemperature Humidity Chamber

Temperature Humidity Controlled Chamber Laboratory Test Chamber

Certification
China Hai Da Labtester certification
China Hai Da Labtester certification
Customer Reviews
Yes we received the machine last week. This Machine was nice, and thank the after-sales serives, was very professional.

—— Peter Maas

The melt flow tester is working very good. The delivery was more faster than expect, your after-sales servies team memembers were nice, and the technical support was perfect.

—— Steve Hubbard

I'm Online Chat Now

Temperature Humidity Controlled Chamber Laboratory Test Chamber

Temperature Humidity Controlled Chamber Laboratory Test Chamber
Temperature Humidity Controlled Chamber Laboratory Test Chamber
Temperature Humidity Controlled Chamber Laboratory Test Chamber Temperature Humidity Controlled Chamber Laboratory Test Chamber Temperature Humidity Controlled Chamber Laboratory Test Chamber Temperature Humidity Controlled Chamber Laboratory Test Chamber Temperature Humidity Controlled Chamber Laboratory Test Chamber Temperature Humidity Controlled Chamber Laboratory Test Chamber Temperature Humidity Controlled Chamber Laboratory Test Chamber Temperature Humidity Controlled Chamber Laboratory Test Chamber

Large Image :  Temperature Humidity Controlled Chamber Laboratory Test Chamber

Product Details:
Place of Origin: China
Brand Name: Haida
Certification: CE,,ISO
Model Number: HD-E702
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Strong Wooden Case
Delivery Time: 15 Days After Order
Payment Terms: L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability: 75 Piece / Pieces Per Month

Temperature Humidity Controlled Chamber Laboratory Test Chamber

Description
Usage: Environmental Stability Temperature And Humidity Control Test Chambers Temp. Range: -70°C~150°C
Temp. & Humid. Accuracy: ± 0.3°C; ± 2 Percent R.H Resolution: 0.01°C, 0.1 Percent, P.I.D Control
Interior Dimension(W×D×H): 100×100×80cm Exterior Dimension(W×D×H): 145x190x135cm
Display: LCD Power: AC220V±10 Percent 50/60Hz
Use: Temperature And Humidity Test Chamber
High Light:

Constant Temperature And Humidity Chamber

,

Temperature Humidity Test Chamber

Temperature Humidity Controlled Chamber Laboratory Test Chamber

 

 

Temperature and humidity chamber.pdf

 

Chamber Summary:

 

Temperature Humidity Laboratory Test Chamber with precise temperature and humidity control system, this equipment provides variety of environmental simulate conditions that industrial research and biological test need. It is used in medicine, textile and food production experiment, as well as in product stability, raw material, packing and lifetime test.

 

 

1. Specifications of Environmental Temperature Humidity Laboratory Test Chamber:

Range – 40 to 150°C

 

Temp/Humidity

HD-E702-100-4

HD-E702-150-4

HD-E702-225-4

 

HD-E702-408-4

HD-E702-800-4

HD-E702-1000-4

Temp-only

HD-E702-100T-4

HD-E702-150T-4

HD-E702-225T-4

 

HD-E702-408T-4

HD-E702-800T-4

HD-E702-1000T-4

Temperature Range:

-40°C ~150°C

Cooling Capacity

~ 2 kW at -20°C

~ 2.5 kW at -20°C

 ~ 4.5 kW at -20°C

 

~ 5.5 kW at-20°C

~ 8 kW at -20°C

~ 8.5 kW at - -20°C

Heating System

~ 5 kW

~ 5 kW

~ 5.5 kW

 

~6.5 kW

~ 8.5 kW

~ 9 kW

Temperature Fluctuation:

±0.5°C

Temperature Gradient:

±0.5°C~±0.2°C

Heating Rate†:

≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

Cooling Rate†:

≥1℃ / min average (Advance model 5 - 15℃ / min)

Humidity Range:

10%~95%RH (Ref to Normal Humidity Range Diagramed)

Humidity Fluctuation:

±1.5%RH~±2.0%RH

Humidity Gradient:

±3%RH

Dimensions

Workspace dimensions
(WxDxH)mm:

500x400x500

HD-E702-100

600x500x500

HD-E702-150

750x500x600

HD-E702-225

 

850x650x800

HD-E702-800

1000x1000x800

HD-E702-800

1000x1000x1000

HD-E702-1000

Exterior dimensions
(WxDxH)mm:

1400x850x1050

1500x950x1050

1650x950x1150

 

1750x1050x1350

1900x1450x1350

1900x1450x1550

Site Requirements

Electrical Supply:

208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

Humidity Water

Distilled Water

Condensate Drain:

1/2" hose connection (gravity drain)

 

 

2. Features of Temperature Humidity Laboratory Test Chamber:

 

1, perfect design: circular shape and surface spray, high-texture appearance, and no reaction with flat handle, easy, safe and reliable.
2, bright, broad vision of the large observation window: The three vacuum coating windows and Philips energy-saving fluorescent lamps, without wipers defogging keep clear observation results can always observe the condition of the test sample.
3, humidification system piping and control circuit separation: humidification system piping and power supply, controller, circuit board separation, avoid the affected pipeline leakage circuit to improve safety.
4, advanced and reliable refrigeration and control systems: closed compressor imported from Europe, imported environmentally friendly refrigerant, a world-renowned brand refrigeration device, imported LCD touch screen controller, friendly interface, easy to learn

 

 

Standard Features:

  • Stainless# 304  steel for interior
  • Paint steel for exterior
  • Foam-insulated door for rigidity and long life
  • Plastic water tank easy for maintenance
  • Observation Window with frost free function
  • High performance refrigeration system
  • Easy user interface for TEMI-880 PLC controller
  • One 100mm cable port/ Customer specified
  • One shelve, 10 Kg loading  & 4 casters included
  • Van Type Sirocco,L134,Fan
  • PID controlled-Stainless Steel Humidifier
  • DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
  • USB port for data output
  • Anti-explosive interior lamps
  • Data logging chart recorders, paperless recorders stored data in the PLC. 

 

Operation

 

Through three interrelated systems: refrigerant cycle system, air circulation system, electrical automatic control system.


1, temperature and humidity chamber refrigerant cycle system: heat the evaporator liquid refrigerant absorbs the air (air is cooled and dehumidified) and begins to evaporate, forming a certain temperature difference, the liquid refrigerant between the refrigerant and air also completely evaporated into gas, after the compressor suction and compression (increased pressure and temperature), the gaseous refrigerant passes through the condenser (air / water) to absorb heat, it condenses into a liquid. Through the expansion valve (or capillary) throttled into low temperature low pressure refrigerant into the evaporator, the refrigerant to complete the cycle.

 

2, The air temperature and humidity chamber ring system: Fan is responsible for the return air from the air sucked The air through the evaporator (cooling, dehumidification), humidifiers, heaters (heating) after delivery outlet to the space required for the user air mixing air and space sent back after the return air.

 

3, temperature and humidity chamber Electric Automation Systems

 

3. Performance of Environmental Temperature Humidity Laboratory Test Chamber:

 

 

System & Performance Options

  • Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed) 
  • Water-cooling system.
  • Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
  • Additional shelves, 50 Kg  loading
  • Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters

 

Questions for Performance Evolution Request: 

 

temperature and humidity test chamber

 

 

Frozen System


Modular cooling system, high efficiency, easy installation and maintenance;
Waterway switchboard separation, reduce security risks;
Flooding leak, leak completely eliminate the potential leak;
DuPont uses environmentally friendly refrigerant, non-polluting;
Cooling system, electric control system number of security mechanisms

 

Control Method


Balance thermostat humidity control system (BTHC), to P.I.D. controlled SSR, the heated humidification system equal to the amount of heat and moisture loss, so long-term stability in use.

 

 

Energy-saving Design


In addition to fully consider the safety of refrigeration units, efficient use of all sectors, but while taking multiple energy saving measures: such as: adjusting the cooling capacity of the refrigeration system, liquid-gas bypass regulation, evaporation temperature regulation, low temperature at any point when the thermostat without heat balance, operating power can be reduced to half, so that operating costs and failure rates of the refrigeration system down to a more state of the economy.
Intelligent automatic transfer system expansion, the load automatically adjust the refrigerant flow + intelligent electric power data value (%) to match heating and cooling (load) Analog output data automatically according to the output value. This design than the traditional design saving more than 30%.

 

(Advanced refrigeration design is especially compact for HD-Series Chambers)

Contact Details
Hai Da Labtester

Contact Person: Kelly

Send your inquiry directly to us (0 / 3000)