Home ProductsEnvironmental Test Chamber

Stability Temperature Humidity Testing Chamber Environment Test Apparatus

Certification
China Hai Da Labtester certification
China Hai Da Labtester certification
Customer Reviews
Yes we received the machine last week. This Machine was nice, and thank the after-sales serives, was very professional.

—— Peter Maas

The melt flow tester is working very good. The delivery was more faster than expect, your after-sales servies team memembers were nice, and the technical support was perfect.

—— Steve Hubbard

I'm Online Chat Now

Stability Temperature Humidity Testing Chamber Environment Test Apparatus

Stability Temperature Humidity Testing Chamber Environment Test Apparatus
Stability Temperature Humidity Testing Chamber Environment Test Apparatus
Stability Temperature Humidity Testing Chamber Environment Test Apparatus Stability Temperature Humidity Testing Chamber Environment Test Apparatus Stability Temperature Humidity Testing Chamber Environment Test Apparatus Stability Temperature Humidity Testing Chamber Environment Test Apparatus Stability Temperature Humidity Testing Chamber Environment Test Apparatus Stability Temperature Humidity Testing Chamber Environment Test Apparatus

Large Image :  Stability Temperature Humidity Testing Chamber Environment Test Apparatus

Product Details:
Place of Origin: China
Brand Name: Haida
Certification: CE,,ISO
Model Number: HD-E702
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: Strong Wooden Case
Delivery Time: 20 days after order confirmed
Payment Terms: L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability: 300 Sets per Month

Stability Temperature Humidity Testing Chamber Environment Test Apparatus

Description
Usage: Constant Temperature And Humidity Testing Machine Temp. & Humid. Accuracy: ± 0.3°C; ± 2 Percent R.H
Temp. & Humid. Regularity: ± 1°C; ± 3 Percent RH Heating Up: -40°C ~ +100°C Within 45 Min
Heating Down: 20°C~ -20°Cwithin 40min Exterior Dimension(W×D×H): 145x190x135cm
Interior Material: Stainless Steel Plate(SUS304) Display: LCD
Weight: Approx. 600 Kg Power: AC220V±10 Percent 50/60Hz
High Light:

environmental testing equipment

,

environmental lab testing equipment

Stability Temperature Humidity Testing Chamber Environment Test Apparatus

 

 

HD-E702-225-7 Climate Chamber.pdf

 

 

International Applications

Stability Temperature Humidity Chamber Environment Test Apparatus is used to detect the material in some performance under a variety of environmental test equipment and a variety of materials, heat, cold, humidity and dry resistant properties, mainly for the aerospace, automotive, electronics and other products to detect quality.

 

 

control method
Balance thermostat humidity control system (BTHC), to P.I.D. controlled SSR, the heated humidification system equal to the amount of heat and moisture loss, so the use of long-term stability

 

 

Equipment structure


Box liner imported stainless steel (SUS304) or 304B welding mirror panel is made of A3 steel box outside the gall spray;
Microcomputer temperature and humidity control, controlling temperature and humidity accurate and reliable;
Large observation window with bright lights to keep the box, and the use of double glazing, ready to clear observation box condition;
With a separate limit temperature alarm system, exceeds the limit temperature is automatically interrupted to ensure the safe operation of experiment is not an accident;
The left side of the box with test hole diameter of 50mm.

 

 

Standard Features of Stability Humidity and Temperature Control Test Apparatus:

  • Stainless# 304  steel for interior
  • Paint steel for exterior
  • Foam-insulated door for rigidity and long life
  • Plastic water tank easy for maintenance
  • Observation Window with frost free function
  • High performance refrigeration system
  • Easy user interface for TEMI-880 PLC controller
  • One 100mm cable port/ Customer specified
  • One shelve, 10 Kg loading  & 4 casters included
  • Van Type Sirocco,L134,Fan
  • PID controlled-Stainless Steel Humidifier
  • DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
  • USB port for data output
  • Anti-explosive interior lamps
  • Data logging chart recorders, paperless recorders stored data in the PLC. 

 

 Performance of Stability Humidity and Temperature Control Test Apparatus:

 

System & Performance Options

  • Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed) 
  • Water-cooling system.
  • Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
  • Additional shelves, 50 Kg  loading
  • Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters

 

Get a performance evaluation to help provide the suitable chambers to you.

 

For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements. 

 

Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you. 

 

 

Stability Temperature Humidity Testing Chamber Environment Test Apparatus 0

(Normal Humidity Range Diagramed)

 

 

 

 Specifications of Stability Humidity and Temperature Control Test Apparatus:

 

Range – 70 to 150°C 

 

Temp/Humidity

HD-E702-100-7

HD-E702-150-7

HD-E702-225-7

 

HD-E702-408-7

HD-E702-800-7

HD-E702-1000-7

Temp-only

HD-E702-100T-7

HD-E702-150T-7

HD-E702-225T-7

 

HD-E702-408T-7

HD-E702-800T-7

HD-E702-1000T-7

Temperature Range:

-70°C ~150°C

Cooling Capacity

~ 2.5 kW at -50°C

~ 3 kW at -50°C

 ~ 5 kW at -50°C

 

~ 6.5 kW at-50°C

~ 8.5 kW at -50°C

~ 9 kW at - -50°C

Heating System

~ 5 kW

~ 5 kW

~ 5.5 kW

 

~6.5 kW

~ 8.5 kW

~ 9 kW

Temperature Fluctuation:

±0.5°C

Temperature Gradient:

±0.5°C~±0.2°C

Heating Rate†:

≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

Cooling Rate†:

≥1℃ / min average (Advance model 5 - 15℃ / min)

Humidity Range:

10%~95%RH (Ref to Normal Humidity Range Diagramed)

Humidity Fluctuation:

±1.5%RH~±2.0%RH

Humidity Gradient:

±3%RH

Dimensions

Workspace dimensions
(WxDxH)mm:

500x400x500

HD-E702-100

600x500x500

HD-E702-150

750x500x600

HD-E702-225

 

850x650x800

HD-E702-800

1000x1000x800

HD-E702-800

1000x1000x1000

HD-E702-1000

Exterior dimensions
(WxDxH)mm:

1400x850x1050

1500x950x1050

1650x950x1150

 

1750x1050x1350

1900x1450x1350

1900x1450x1550

Site Requirements

Electrical Supply:

208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

Humidity Water

Distilled water

Condensate Drain:

1/2" hose connection (gravity drain)

 

 

working principle


Temperature and humidity chamber by a thermostat (heating, cooling) and humidification of two parts. At the top of the cabinets by installing a rotary fan, air is discharged into the tank to achieve gas circulation, balance cabinets temperature and humidity, the built-in cabinet temperature and humidity sensor data acquisition, spread of temperature and humidity controller (Micro information processor) editing process, temperature and humidity control instructions issued by The air heating unit inside the condenser and heat sink together to complete evaporation unit.

 

 

Heating system


Far-infrared heating using nickel-chromium alloy heating wire heating speed;
High temperature, low temperature completely independent systems;
Temperature control P · I · D + S · S · R system with channel coordination control;
Temperature control the output power by the microcomputer calculus, to achieve high accuracy and high efficiency power efficiency.

 


Cooling System


Refrigeration cycle are used against the card if the cycle, which consists of two isothermal and two adiabatic processes, whose process is as follows: a refrigerant through the compressor adiabatic compression to a higher pressure, the power consumption of the exhaust gas temperature, after the temperature of the refrigerant through the condenser and other places in and around medium heat exchange medium heat to four weeks. After the refrigerant flows through the shutoff valve adiabatic expansion work, when the refrigerant temperature decreases. Finally, the refrigerant passes through the evaporator isothermal heat from high temperature object, the object to be cooled so that the temperature is lowered. This loop again and again to achieve the purpose of cooling.
       Design and Application of refrigeration system energy regulation technology, an effective treatment can guarantee but also on energy and cooling capacity refrigeration systems can be adjusted in the case of the normal operation of the refrigeration unit, so that operating costs of the refrigeration system down to a more state of the economy.

 

 

energy-saving design


In addition to fully consider the safety of refrigeration units, efficient use of all sectors, but while taking multiple energy saving measures: such as: adjusting the cooling capacity of the refrigeration system, liquid-gas bypass regulation, evaporation temperature regulation, low temperature at any point when the thermostat without heat balance, operating power can be reduced to half, so that operating costs and failure rates of the refrigeration system down to a more state of the economy.
Intelligent automatic transfer system expansion, the load automatically adjust the refrigerant flow + intelligent electric power data value (%) to match heating and cooling (load) Analog output data automatically according to the output value. This design than the traditional design saving more than 30%.

 

 

The daily maintenance


1) temperature and humidity chamber refrigeration system is the core of the chamber, please at least once a year to check all of the pipe there is no leakage, etc. in the various joints and welding mouth, if oil leakage should be promptly treated.


2) wet and dry bulb and wet cloth should always check, when the test surface is not clean cloth or harden, or more than 85 ℃ high temperature control, the temperature and humidity control to continue to do before. The accuracy of inspection, if non-absorbent, please replace it related to measuring humidity, the test cloth is generally a replacement in March, when we use a clean cloth to replace the body temperature, should be replaced with a new test cloth and then wash your hands sink clean.

 

3) When the time arrives to take the test product after product, must be in the off state, and the staff must wear dry, anti-power, moisture gloves handling products.

 

4) ground temperature and humidity chamber at the bottom and around the body to be kept clean, so as not to produce a lot of dust suction unit accidents and reduce performance.

 

 

4. Environment Stability Humidity and Temperature Control Test Apparatus view:

 

Stability Temperature Humidity Testing Chamber Environment Test Apparatus 1

 

Our Services

 

If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.

 

 

FAQ

Why choose us?

1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator.

2.Excellent After sale Service:
18 months warranty. Besides, we can help you to repair your problem controller freely, even it's not from our factory. What you need to do is to send us the controller.

3.Commitment:
We will sign a letter of commitment while we sign the contract, which will improve your confidence to us.

4.Good Packaging:

Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

 

How to Contact Us?

Please Send your inquiry Details in the below for our quotation,Click "Send" Now!

 

Contact Details
Hai Da Labtester

Contact Person: Kelly

Send your inquiry directly to us (0 / 3000)