Product Details:
|
Usage: | Organic Materials Ozone | Warranty Year: | 1 Year |
---|---|---|---|
Interior Size (WxDxH): | 250x250x250mm | Certificate: | ISO,, CE Etc |
Accuracy: | ± 1% | Temp. (optional): | Room Temp.~200°C Or 300°C |
Motor: | 1/4 HP | Electrothermal Tube: | 3 KW |
Weight: | 250kg | Power: | 1#, AC 220V/14.5A |
Use: | Ozone Test Chamber | ||
High Light: | ozone test chamber,accelerated aging calculator |
Organic materials Ozone Test CE ISO short circuit Safety device Aging chamber
Product description:
Organic materials Ozone Test CE ISO short circuit Safety device Aging chamber is suitable for testing compatibility of unvulcanized rubber and other products under non-direct light, exposing to ozone-containing air and certain environment. Also used to evaluate the ozone aging resisting performance of rubber and the protectic efficacy of the antiozonant so as to take the effective ozone-aging resisting measures to extend the life span of the rubber products.
Structural features of ozone aging chamber:
1, Box using CNC machining, no side door handle, easy to operate.
2, box liner made of high grade stainless steel plates, steel box outside the gall bladder using A3 spray, increasing the appearance of texture and cleanliness.
3, heating fever poses heating, heating up fast, uniform temperature distribution.
4, a reasonable position to set up a transparent door window for the observation of changes in the indoor samples. Multi-layer hollow glass observation window, glue chip inside the conductive film having a transparent, heat, frost and other advantages difficult to produce steam.
5, the device uses the long axis of the fan motor stirring, high temperature resistance of stainless steel multi-blade impeller, the strength to achieve vertical diffusion convection loop, so that the temperature inside the lab uniform and has remained stable.
Specifications:
Ozone Test Chamber
1. We are amnufacturer, offer best price for you.
2. Ozone concentration 0~1000 pphm
3. Both static and dynamic tests are available.
4. 1 Year Warranty & Lifelong Technical Support.
Technical parameters:
Inner chamber size W*H*D(mm) | 500*600*500 | 500*750*600 | 600*850*800 | 1000*1000*800 | |||||
Exterior chamber size W*H*D(mm) | 950*1500*1050 | 950*1650*1150 | 1050*1750*1350 | 1450*1900*1350 | |||||
Temperature Range | RT to 90°C | ||||||||
Humidity Range | 45%RH ~98%RH | ||||||||
Performance | Temp.&Humi fluctuation | ±0.2°C, ±0.5%RH | |||||||
Temp.&Humi.uniformity |
±1.5°C,±2.5% RH when RH is ≤ 75%,±4% RH when RH is > 75% (tested with the empty chamber, 30 minutes after stabilization) |
||||||||
Temp.&humi. Resolution | 0.01°C,0.1%RH | ||||||||
Ozone concentration | 0 to 1000 PPHM | ||||||||
Ozone control accuracy | ±10% | ||||||||
Ozone generation | Static emissions | ||||||||
Sample rotating speed | 1 times per minute | ||||||||
Material | Exterior chamber material | Stainless steel plate+Powder Coated | |||||||
Interior chamber material | SUS#304 stainless steel plate | ||||||||
Insulation | PU & Fiberglass wool | ||||||||
Ozone analyzer | Imported ozone density analyzer | ||||||||
Ozone generator | Silent discharge type ozone generator | ||||||||
System | Wind Circulation | Sirocco fan | |||||||
Heating system | SUS#304 stainless steel high-speed heater | ||||||||
Humidifying | Surface evaporating system | ||||||||
Cooling | Imported compressor,finned type evaporator,air-cooling condenser | ||||||||
Dehumidifying | ADP critical dewpoint cooling/dehumidifying method | ||||||||
Controller | Digital electronic indicators+S.S.R.With PID automatic calculation capability | ||||||||
Other Components | Vacuum glass inspection window,cable port(50mm),control status indicator lights, chamber lamp,loading shelves (2pcs for free) | ||||||||
Safety Devices | Overheating circuit-breaker,compressor overload protection,control system overload protection, humidifying system overheating protection, breakdown indicator light | ||||||||
Power supply | AC 1 phase 220V; 3 phase 380V 60/50Hz |
Features:
1. External chamber:Arc design,nice shape,surface electrostatic spray.
2. Inner chamber:SUS#304 stainless steel, anti-corrosion and water resistance.
3. The door is in the front side, with a transparent window (220*320mm) for observation indoor specimen (lighting inside), which has theadvantages of transparent ,heat insulation, explosion-proof and so on.
4. Air duct of wind way is the same direction as the specimen growth. High tensile silicone seal used in between test door and body to ensure the test area closed.
5. Cooling system: Installed at the bottom, Tecumseh compressor original France.
6. High-quality fixed wheels in the bottom, easy to move.
7. Heating system: completely independent,nickel chromium alloy electric heater.
8. Heater control way :contact cycle pules width modulated,SSR(solid state relays)
9. Output power calculus by microcomputer to control a smooth,reliable.
Corresponding standard:
JIS K 6259 , ASTM1149 , ASTM1171, ISO1431, DIN53509 , GB/T13642, GB/T 7762-2003
GB 2951
Ozone Systems:
As a result of the intermediate frequency high voltage power supply, due to the corona electrode does not produce heat, so that the concentration of ozone generated stable, will not change with the level of working hours or gas flow caused by the ozone concentration decreases. The high-frequency ceramic surface discharge corona generator due to the high frequency voltage discharge, when the temperature of the discharge region can not be effectively dissipated, leading to decomposition of ozone due to overheating, use under high flow conditions appropriate
The use of integrated ozone concentration ﹑ temperature and humidity controller (setting mode for the touch of a button type), high integration, good reliability, LED display, display resolution temperature (0.1 ℃), humidity (0.1% RH), the ozone concentration ( 1pphm), PID setpoint control, easy to operate
Ozone chamber ozone aging test start:
Open the green power button. The chamber temperature to 40 degrees, and other chamber temperature to stabilize. Return 0 meter ozone, ozone, 20 minutes after the open button. Meter set to see the instrument instruction manual;
When the humidity test, Wuhan is still measured to remind you to check whether there is water inside the tank, dry water. Open the heat button. The test instrument adjusted to the required test temperature, open cooling button.
Care and maintenance methods:
1, ozone aging test chamber must be specified if the hand operation, custody and maintenance, so as to ensure the normal operation of the device.
2, long-term use of equipment, spare parts, motor blower unit, wheel deceleration devices,
If abnormal noise, should be checked, and pay attention to regular cleaning fuel.
3, if the device is manifold, the ozone generator power, must ensure that the valve is open all the way, otherwise the gas can not get out, will result in discharge burn.
4, keep the box clean and tidy appearance; avoid dust intrusion cabinet; after completion of the test, the machine power off.
Ozone aging test is to ensure that the essential part of high-quality products, and maintenance of equipment enabling it to extend the life more conducive to product testing to ensure its quality.
Contact Person: Kelly